version 1.12











 


From 3/8” OD to 12” IPS and from 3/8” wall to 4” wall, we have all of the insulation necessary to insulate any type of piping system.  We stock Polymer Foam, EPDM Rubber and Fiberglass Insulation.  The Polymer Insulation is typically used in Plumbing Applications.  The EPDM Rubber Insulation can also be used in Plumbing Applications but is most often times used for Refrigeration and Chilled Water Systems.  Fiberglass Insulation is generally used in high temperature applications such as boiler and steam lines.  Insulation is necessary to conserve energy and prevent condensation.  Please see below and see the different types of insulation we carry along with some of the specifics surrounding the products.

Polymer Insulation
Polymer InsulationWe stock Polymer Foam insulation ½”ID to 4”ID and from ½ Wall to 1” Wall.  This insulation is only available in 6ft lengths.  Polymer Foam Insulation is a self-sealing flexible insulation.  It is used to control heat gain, prevent condensation and prevent heat loss on hot water systems.  It can be used in commercial, residential and industrial applications.

 

 

Fiberglass Insulation
Fiberglass InsulationFiber Glass Insulation is made from rotary glass fibers and only available in 3ft lengths.  It designed for iron pipe and copper tubing.  This insulation is unique in that paint may be applied to the outer jacket after installation.  The fiberglass insulation is designed so that it will not soften or separate when exposed to higher temperatures and can withstand temperatures up to 850 degrees Fahrenheit. 


Aeroflex Rubber Insulation

Continuous Tube
Aeroflex Rubber Insulation - Continuous TubeAerocel® continuous tube and sheet insulation is a flexible, closed cell and light weight elastomeric material designed for insulating liquid cooling and heating lines. Aerocel® continuous tube is available in 3/8”, 1/2”and 3/4” thickness, and popular sizes up to 1 1/8” ID. The closed-cell structure of Aerocel® continuous tube pipe insulation makes it an efficient insulation.


White and Gray

Aeroflex Rubber Insulation - White and GrayAerocel White/Gray 25/50 Tubular lnsulation is a flexible, closed cell and light weight EPDM* based elastomeric material designed for insulating liquid cooling and heating lines. 1/2", 3/4" and 1" wall, in popular I.D. sizes up to 2 5/8". The closed-cell structure of Aerocel Pipe lnsulation makes it an efficient insulation.



Aerocel CG

Aeroflex Rubber Insulation - AerocelAerocel-CG Tube and Sheet lnsulation is a flexible, closed cell and light weight elastomeric material designed for insulating liquid cooling and heating lines. Aerocel-CG is available in 3/8", 1/2", 3/4" and 1" thickness, and popular sizes up to 1 1/8" ID. The closed-cell structure of Aerocel Pipe lnsulation makes it an efficient insulation.

 

Aerocel SSPT (Stay Seal with Pro Tape)
Aeroflex Rubber Insulation - Aerocell SSPTAerocel-SSPT(Stay-Seal® with Protape)Tube and Sheet lnsulation is a flexible, closed-cell and light weight EPDM* based elastomeric material designed for insulating liquid cooling and heating lines. 3/8", 1/2", 3/4",1" , 1-1/4", 1-1/2", 2", 2-1/2" and 3" wall in popular I.D. sizes up to 10" IPS. The closed-cell structure of Aerocel Pipe lnsulation makes it an efficient insulation.
 

Aerofit Fitting Covers
Aerofit Fitting CoversAerocel® AeroFit® Insulating Fitting Covers are designed for insulating warm or cold piping fittings without the need to field-fabricate these shapes, saving labor and providing enhanced project performance. Aerocel® AeroFit® Elastomeric Insulating Fitting Covers are supplied in ¼”, 3/8”, 1/2”, 3/4”, 1”, 1-1/4”, 1-1/2” and 2” thickness’, in popular I.D. sizes up to 6” IPS, as copper 90° long-radius and short-radius elbows, and copper refrigeration suction line P-Trap shapes.

Aerofix – U
Aerofix – UAerofix-U is a polymeric rigid foam hanger with a foam tape inner lining which supports and absorbs vibration of operating pipelines. The outer-cover consists of a special rubber tape which seals the hanger completely after installation in order to prevent condensation. Its strong closed cell structure is ideal for liquid cooling pipes to prevent condensation and save energy. It is used primarily for repairing and properly supporting pipes in chilled water or refrigeration systems. 

Tape and Glue
Aeroflex also offers a variety of tapes and glues to help connect or repair insulation.  These unique materials are designed to handle a variety of temperatures and chemically fuse to the insulation creating one solid unit.    
 

TOP
 